Lab Report Osmosis Assignment

Lab Report Osmosis Assignment Words: 1401

We studied the rate of osmosis in artificial cells by creating five different dialysis bags with different concentrations of OTOH SUcrose and water and calculating the cumulative change in weight ever 10 minutes for 90 minutes. Our results for the artificial cells showed different concentrations moved from high to low concentrations- through hypotonic movement or hypersonic movement. Introduction The main purpose of this paper is to assess the rate of change with osmosis for different concentrations of sucrose in artificial cells.

Since the human body is composed of trillions of cells that contain roughly 85% of water, makes osmosis a very important concept (Carmichael, Grab and Winger). The forces that affect osmosis are the concentrations of solutes surrounding the cell or inside of the cell. Water will then move across the cell membrane and create a balance of water between the cell and its environment (Race et al. 133).

Don’t waste your time!
Order your assignment!


order now

In order to calculate the average rate of change for our artificial cells, we must understand tonic as the ability of a nearby solution to cause a cell to lose or gain water, depending on its concentration of non-penetrating solutes relative to solutes inside the cell (Race et al. 133). The dialysis bags used in this experiment eave membranes which are selectively permeable, which only allows particles specifically small enough to pass through (Carmichael, Grab and Winger).

In a hypotonic solution, water goes into the cell because the solute is more concentrated inside the cell, while in a hypersonic solution, water moves out of the sell because the solute is more concentrated outside of the cell. We are testing the effect of osmosis on different concentrations of artificial cells by calculating the cumulative change in weight and the corrected cumulative changes in weight and by determining whether a solution is hypersonic, hypotonic or isotonic. We predicted that a dialysis bag holding tap water in a beaker also containing tap water is in an isotonic solution.

While 20% sucrose, 40% sucrose and 60% sucrose in beakers containing tap water is considered hypotonic solutions. Lastly the dialysis bag holding tap water in a beaker containing 40% sucrose is a hypersonic solution. This will result in isotonic solutions remaining at the same weight, hypotonic solutions gaining weight and hypersonic solutions losing weight. We tested this by creating the five different alkalis bags with different concentrations of sucrose in order to measure the weight change in grams of the bag after nine 10 minute increments. Methods and Materials This experiment took place on Monday, February 6th, 2011.

During this time, we tested the effects of different sucrose concentrations on the rate of osmosis in artificial cells we made with dialysis tubing. We studied five different dialysis bags containing ml of different concentrations of tap water and sucrose. Two contained tap water while three contained different concentrations of sucrose, varying from 20% to 60%. Each bag was placed in a beaker surrounded by either tap water or 40% sucrose. We began the experiment by soaking the dialysis tubes to prepare them for the sucrose concentrations they would be filled with.

Taking each bag, two were filled with ml afoot water, one filled with ml of sucrose, one with ml of 40% SUcrose and another with ml of sucrose. Each bag was clamped closed. All the bags were weighed before being placed in their corresponding beakers in order to record their initial weight in grams. The bags were put in their corresponding beakers, all of which contained AP water, except beaker #5 (tap water bag #5 was placed in beaker #5 which instead of holding water, was filled with 40% sucrose) concurrently, recording the time.

In the same manner in which the bags were placed in the beakers simultaneously, remove the bags every 10 minutes, and record the weight of each bag. This process should be repeated for at least 90 minutes total. This data was analyzed by calculating the cumulative change in weight for each dialysis bag. This was done from subtracting the weight of each bag from the initial weight of the bag. Doing so, allows the weight of each bag to be initially error. For that, we must calculate the corrected cumulative change in weight.

For each time interval of 10 minutes, we subtracted the change in weigh of bag #1 (tap water) from the weight of each bag at the specific time measure- this corrected any oscillations. Results The corrected cumulative change in weight due to osmosis from different concentrations of sucrose and tap water, are shown in Figure One. This figure shows the weight change in grams for every interval of 10 minutes. Using the corrected cumulative change in weight eliminates bag #1 because its average ate of change will always be zero.

Using the corrected cumulative change, we can monitor the rate of change for each bag, and correlate the rate of change to the rate of osmosis. For bag #2, the slope, or the rate of osmosis was y = 0. Xx – 1. 7293, displaying a slow but obvious increase in weight, or a hypotonic solution, when the solute was more concentrated inside the cell and water moved into the cell. Bag #3 continues to show this trend with a quicker rate of y = 1. Xx – 2. 4807, which water enters this bag as a hypotonic solution. Bag #4, which a rate of y = -1. Xx + 1. 9043, shows a hypersonic solution in which the low concentration solute, causing water inside the dialysis bag, to move out. Although it was expected for for bag #5, which was tap water submersed in 40% sucrose, to be hypersonic, the rate of osmosis was y = 1. Xx – 0. 1679, which demonstrates a hypotonic solution, or water entering the cell, or moving from a high concentration of the solute to a low concentration. These results prove that the direction of osmosis does directly affect the rate of osmosis.

If the slope begins with a negative x value, the solution is indeed a hypotonic solution, that when surrounding a cell will cause the cell to lose water, moving from a high concentration to a lower concentration (Race et al. 133). The slopes which begin with a positive x value demonstrate a hypotonic solution, which causes a cell to take in water (Race et al. 133). This shows that the direction of osmosis is directed related to the rate of osmosis, or vice versa. The rate of osmosis ultimately determines the direction of osmosis.

Depending on which direction osmosis is going- hypersonic, isotonic or hypotonic, determines the rate of osmosis, or the rate of change for each dialysis bag. Or by the means of our experiment, the direction of osmosis was determined by the rate of change in each bag, or the rate of osmosis. Discussion Throughout the study it was concluded that different concentrations of sucrose are allow different rates and directions of osmosis. The results show that the rate of osmosis is directly related to the direction of osmosis, or vice versa.

This proposal does not match with our quantitative prediction. Our results for the artificial cells showed different concentrations moved from high to low concentrations- through hypotonic movement or hypersonic movement; however gag #3 with 40% sucrose was expected to be a hypotonic solution, while it was a hypersonic solution. This falsified hypothesis could be due to the explanation that in an animal cell, when a hypersonic solution, the cell experiences creation.

The dialysis tubing creates a theoretical flaw in our experiment because the tubing has a molecular weight cut off of a maximum of 14 kilotons, while the average human cell may have a larger or smaller molecular weight cut off, allowing the cell to experience different ethnicities. In order to obtain more accurate results, modifications should be made. More drastic concentrations of sucrose in the dialysis tubing should be tested in order to find the extremes of the rate of change for osmosis.

The study enhances the present scholarship in this area by exposing osmosis along a free energy gradient. However, other experiments could increase our knowledge about the relationship between concentration gradients and rates. An experiment that includes the idea that the selectively permeable membrane moves, might allow for more accurate results (Patella and Waters). The qualified location mirrors the volume of each side of he membrane, which affects the total number of particles on each side (Patella and Waters).

How to cite this assignment

Choose cite format:
Lab Report Osmosis Assignment. (2019, Jan 31). Retrieved December 23, 2024, from https://anyassignment.com/chemistry/lab-report-osmosis-assignment-55924/